    AC WITHSTANDING

    Output-Voltage Range

    0.050kV~ 5.000kV ac

    Output-Voltage Resolution

    2V/step

    Output-Voltage Accuracy

    ± (1% of setting +5V) [no load]

    Maximum Rated Load

    500 VA (5kV/100mA)

    Maximum Rated Current

    100mA (0.5kV < V ≦ 5kV)

    10mA (0.05kV ≦ V≦ 0.5kV)

    Output-Voltage Waveform

    Sine wave

    Output-Voltage Frequency

    50 Hz / 60 Hz selectable

    Voltage regulation

    ± (1% of reading +5V) [full load → no load]

    Voltmeter Accuracy

    ± (1% of reading+ 5V)

    Current Measurement Range

    0.001mA~100.0mA

    Current Best Resolution

    0.001mA / 0.01mA / 0.1mA

    AC Current Measurement Accuracy

    ±(1.5% of reading +30 counts) when HISET < 1.11mA

    ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA

    Window Comparator Method

    Yes

    ARC Detect

    Yes

    RAMP (Ramp-Up Time)

    0.1~999.9s

    TIMER (Test Time)*

    OFF, 0.5s~999.9s

    Sweep Function*

    Yes

    GND

    ON/OFF

    DC WITHSTANDING

    Output-Voltage Range

    0.050kV~ 6.000kV dc

    Output-Voltage Resolution

    2V/step

    Output-Voltage Accuracy

    ± (1% of setting +5V) [no load]

    Maximum Rated Load

    100W (5kV/20mA)

    Maximum Rated Current

    20mA (0.5kV < V ≦ 6kV)

    2mA (0.05kV ≦ V≦ 0.5kV)

    Voltage regulation

    ± (1% of reading +5V) [full load → no load]

    Voltmeter Accuracy

    ± (1% of reading+ 5V)

    Current Measurement Range

    0.001mA~20.0mA

    Current Best Resolution

    0.001mA / 0.01mA / 0.1mA

    DC Current Measurement Accuracy

    ±(1.5% of reading +30 counts) when HISET < 1.11mA

    ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA

    Window Comparator Method

    Yes

    ARC Detect

    Yes

    RAMP (Ramp-Up Time)

    0.1s~999.9s

    TIMER (Test Time)*

    OFF, 0.5s~999.9s

    Sweep Function*

    Yes

    GND

    ON/OFF

    INSULATION RESISITANCE

    Output-Voltage

    50V~1000V dc

    Output-Voltage Resolution

    50V/step

    Output-Voltage Accuracy

    ± (1% of setting +5V) [no load]

    Resistance Measurement Range

    0.001G Ω ~ 50.00G Ω

     

    Test voltage

    Measurable Range

    Accuracy

     

    50V≦V≦450V

    0.001~ 0.050G Ω

    0.051~ 2.000G Ω

    ±(5% of reading +1 count)

    ±(10% of reading +1 counts)

     

    500V≦V≦1000V

    0.001~ 0.500G Ω

    0.501~ 9.999G Ω

    10.00~ 50.00G Ω

    ±(5% of reading +1 count)

    ±(10% of reading +1 count)

    ±(20% of reading +1 count)

    Window Comparator Method

    Yes

    Output Impedance

    600k Ω

    RAMP (Ramp-Up Time)

    0.1s~999.9s

    TIMER (Test Time)

    0.5s~999.9s

    Sweep Function*

    Yes

    GND

    OFF (fixed)

    GROUND BOND

    Output-Current Range

    03.00A~32.00A ac

    Output-Current Resolution

    0.01A

    Output-Current Accuracy

    3A≦I≦8A : ± (1% of setting +0.2A)

    8A<I≦32A : ± (1% of setting +0.05A)

    Test-Voltage

    6Vac max. (open circuit)

    Test-Voltage Frequency

    50 Hz / 60 Hz selectable

    Resistance Measurement Range

    10m Ω~650.0m Ω

    Resistance Measurement Resolution

    0.1m Ω

    Resistance Measurement Accuracy

    ± (1% of reading +2m Ω)

    Window Comparator Method

    Yes

    TIMER (Test Time)

    0.5s~999.9s

    Sweep Function*

    Yes

    GND

    OFF (fixed)

    Test Method

    Four Terminal

    MEMORY

    Single Step Memory

    MANU : 100 blocks

    Automatic Testing Memory

    AUTO : 100 blocks, menu per auto : 16

    INTERFACE

    Rear Output

    Standard

    RS232

    Standard

    USB (Device)

    Standard

    GPIB

    Option

    Remote Terminal (Front)

    Standard

    SIGNAL IO

    Standard

    General

    DISPLY

    240 x 64 Ice Blue Dot matrix LCD

    POWER SOURCE

    AC100V/120V/220V/230V ±10%, 50/60Hz

    POWER CONSUMPTION

    1000VA max.

    DIMENSIONS & WEIGHT

    330(W) x 148(H) x 587(D) mm (GPT-9904),

    330(W) x 148(H) x 482(D) mm (GPT-9903A/9902A/9901A)

    approx.27kg(Max)