GW Instek GPT-9800 Series Safety Tester
AC WITHSTANDING | |||
Output-Voltage Range | 0.050kV~ 5.000kV ac | ||
Output-Voltage Resolution | 2V/step | ||
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | ||
Maximum Rated Load | 200 VA (5kV/40mA) | ||
Maximum Rated Current | 40mA (0.5kV < V ≦ 5kV) 10mA (0.05kV ≦ V≦ 0.5kV) | ||
Output-Voltage Waveform | Sine wave | ||
Output-Voltage Frequency | 50 Hz / 60 Hz selectable | ||
Voltage regulation | ± (1% of reading +5V) [full load → no load] | ||
Voltmeter Accuracy | ± (1% of reading+ 5V) | ||
Current Measurement Range | 0.001mA~40.0mA | ||
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | ||
AC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA | ||
Window Comparator Method | Yes | ||
ARC Detect | Yes | ||
RAMP (Ramp-Up Time) | 0.1s~999.9s | ||
TIMER (Test Time)* | OFF, 0.5s~999.9s | ||
Sweep Function* | NOT Support | ||
GND | ON/OFF | ||
DC WITHSTANDING | |||
Output-Voltage Range | 0.050kV~ 6.000kV dc | ||
Output-Voltage Resolution | 2V/step | ||
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | ||
Maximum Rated Load | 50W (5kV/10mA) | ||
Maximum Rated Current | 10mA (0.5kV < V ≦ 6kV) 2mA (0.05kV ≦ V≦ 0.5kV) | ||
Voltage regulation | ± (1% of reading +5V) [full load → no load] | ||
Voltmeter Accuracy | ± (1% of reading+ 5V) | ||
Current Measurement Range | 0.001mA~10.0mA | ||
Current Best Resolution | 0.001mA / 0.01mA / 0.1mA | ||
DC Current Measurement Accuracy | ±(1.5% of reading +30 counts) when HISET < 1.11mA ±(1.5% of reading +3 counts) when HISET ≧ 1.11mA | ||
Window Comparator Method | Yes | ||
ARC Detect | Yes | ||
RAMP (Ramp-Up Time) | 0.1s~999.9s | ||
TIMER (Test Time)* | OFF, 0.5s~999.9s | ||
Sweep Function* | NOT Support | ||
GND | ON/OFF | ||
INSULATION RESISITANCE | |||
Output-Voltage | 50V~1000V dc | ||
Output-Voltage Resolution | 50V/step | ||
Output-Voltage Accuracy | ± (1% of setting +5V) [no load] | ||
Resistance Measurement Range | 1M Ω~ 9500M Ω | ||
| Test voltage | Measurable Range | Accuracy |
| 50V≦V≦450V | 1 ~ 50M Ω 51 ~ 2000M Ω | ±(5% of reading +1 count) ±(10% of reading +1 counts) |
| 500V≦V≦1000V | 1 ~ 500M Ω 501 ~ 9500M Ω | ±(5% of reading +1 count) ±(10% of reading +1 count) |
Window Comparator Method | Yes | ||
Output Impedance | 600k Ω | ||
RAMP (Ramp-Up Time) | 0.1s ~999.9s | ||
TIMER (Test Time) | 0.5s~999.9s | ||
GND | OFF (fixed) | ||
GROUND BOND | |||
Output-Current Range | 03.00A~30.00A ac | ||
Output-Current Resolution | 0.01A | ||
Output-Current Accuracy | 3A≦I≦8A : ± (1% of setting +0.2A) 8A<I≦30A : ± (1% of setting +0.05A) | ||
Test-Voltage | 6Vac max. (open circuit) | ||
Test-Voltage Frequency | 50 Hz / 60 Hz selectable | ||
Resistance Measurement Range | 10m Ω~650.0m Ω | ||
Resistance Measurement Resolution | 0.1m Ω | ||
Resistance Measurement Accuracy | ± (1% of reading +2m Ω) | ||
Window Comparator Method | Yes | ||
TIMER (Test Time) | 0.5s~999.9s | ||
Sweep Function* | NOT Support | ||
Test Method | Four Terminal | ||
MEMORY | |||
Single Step Memory | MANU : 100 blocks | ||
Automatic Testing Memory | AUTO : 100 blocks, menu per auto : 16 | ||
INTERFACE | |||
RS232 | Standard | ||
USB (Device) | Standard | ||
GPIB | Option | ||
Remote Terminal (Front) | Standard | ||
SIGNAL IO | Standard | ||
General | |||
DISPLY | 240 x 64 Ice Blue Dot matrix LCD | ||
POWER SOURCE | AC100V/120V/220V/230V ±10%, 50/60Hz | ||
POWER CONSUMPTION | Max. 500VA | ||
DIMENSIONS & WEIGHT | 330(W) x 148(H) x 452(D) mm (Max.), Approx.19kg max. |